Last data update: May 06, 2024. (Total: 46732 publications since 2009)
Records 1-4 (of 4 Records) |
Query Trace: Turgeon D[original query] |
---|
Implementation of the World Health Organization regional office for Africa Stepwise Laboratory Quality Improvement Process Towards Accreditation
Ndihokubwayo JB , Maruta T , Ndlovu N , Moyo S , Yahaya AA , Coulibaly SO , Kasolo F , Turgeon D , Abrol AP . Afr J Lab Med 2016 5 (1) 280 Background: The increase in disease burden has continued to weigh upon health systems in Africa. The role of the laboratory has become increasingly critical in the improvement of health for diagnosis, management and treatment of diseases. In response, the World Health Organization Regional Office for Africa (WHO AFRO) and its partners created the WHO AFRO Stepwise Laboratory (Quality) Improvement Process Towards Accreditation (SLIPTA) program. SLIPTA implementation process: WHO AFRO defined a governance structure with roles and responsibilities for six main stakeholders. Laboratories were evaluated by auditors trained and certified by the African Society for Laboratory Medicine. Laboratory performance was measured using the WHO AFRO SLIPTA scoring checklist and recognition certificates rated with 1-5 stars were issued. Preliminary results: By March 2015, 27 of the 47 (57%) WHO AFRO member states had appointed a SLIPTA focal point and 14 Ministers of Health had endorsed SLIPTA as the desired programme for continuous quality improvement. Ninety-eight auditors from 17 African countries, competent in the Portuguese (3), French (12) and English (83) languages, were trained and certified. The mean score for the 159 laboratories audited between May 2013 and March 2015 was 69% (median 70%; SD 11.5; interquartile range 62-77). Of these audited laboratories, 70% achieved 55% compliance or higher (2 or more stars) and 1% scored at least 95% (5 stars). The lowest scoring sections of the WHO AFRO SLIPTA checklist were sections 6 (Internal Audit) and 10 (Corrective Action), which both had mean scores below 50%. Conclusion: The WHO AFRO SLIPTA is a process that countries with limited resources can adopt for effective implementation of quality management systems. Political commitment, ownership and investment in continuous quality improvement are integral components of the process. Copyright © 2016. The Authors. Licensee: AOSIS. |
Implementing laboratory quality management systems in Mozambique: the Becton Dickinson-US President's Emergency Plan for AIDS Relief Public-Private Partnership initiative
Skaggs B , Pinto I , Masamha J , Turgeon D , Gudo ES . J Infect Dis 2016 213 Suppl 2 S47-52 BACKGROUND: Mozambique's ministry of health (MOH) recognized the need to establish a national laboratory quality assurance (NLQA) program to improve the reliability and accuracy of laboratory testing. The Becton Dickinson-US President's Emergency Plan for AIDS Relief Public-Private Partnership (PPP) was used to garner MOH commitment and train a cadre of local auditors and managers to support sustainability and country ownership of a NLQA program. METHODS: From January 2011 to April 2012, the World Health Organization Regional Office for Africa Stepwise Laboratory Quality Improvement Process Towards Accreditation (SLIPTA) checklist and the Strengthening Laboratory Management Towards Accreditation (SLMTA) curriculum were used in 6 MOH laboratories. PPP volunteers provided training and mentorship to build the capacity of local auditors and program managers to promote institutionalization and sustainability of the program within the MOH. RESULTS: SLIPTA was launched in 6 MOH laboratories, and final audits demonstrated improvements across the 13 quality system essentials, compared with baseline. Training and mentorship of MOH staff by PPP volunteers resulted in 18 qualified auditors and 28 managers/quality officers capacitated to manage the improvement process in their laboratories. CONCLUSIONS: SLIPTA helps laboratories improve the quality and reliability of their service even in the absence of full accreditation. Local capacity building ensures sustainability by creating country buy-in, reducing costs of audits, and institutionalizing program management. |
Attaining ISO 15189 accreditation through SLMTA: a journey by Kenya's National HIV Reference Laboratory
Gachuki T , Sewe R , Mwangi J , Turgeon D , Garcia M , Luman ET , Umuro M . Afr J Lab Med 2014 3 (2) 216 BACKGROUND: The National HIV Reference Laboratory (NHRL) serves as Kenya's referral HIV laboratory, offering specialised testing and external quality assessment, as well as operating the national HIV serology proficiency scheme. In 2010, the Kenya Ministry of Health established a goal for NHRL to achieve international accreditation. OBJECTIVES: This study chronicles the journey that NHRL took in pursuit of accreditation, along with the challenges and lessons learned. METHODS: NHRL participated in the Strengthening Laboratory Management Toward Accreditation (SLMTA) programme from 2010-2011. Improvement projects were undertaken to address gaps in the 12 quality system essentials through development of work plans, team formation, training and mentorship of personnel. Audits were conducted and the scores used to track progress along a five-star grading scale. Standard quality indicators (turnaround time, specimen rejection rates and service interruptions) were measured. Costs of improvement projects and accreditation were estimated based on expenditures. RESULTS: NHRL scored 45% (zero stars) at baseline in March 2010 and 95% (five stars) after programme completion in October 2011; in 2013 it became the first public health laboratory in Kenya to attain ISO 15189 accreditation. From 2010-2013, turn-around times decreased by 50% - 95%, specimen rejections decreased by 93% and service interruptions dropped from 15 to zero days. Laboratory expenditures associated with achieving accreditation were approximately US $36 500. CONCLUSION: International accreditation is achievable through SLMTA, even for a laboratory with limited initial quality management systems. Key success factors were dedication to a shared goal, leadership commitment, team formation and effective mentorship. Countries wishing to achieve accreditation must ensure adequate funding and support. |
Determination of total homocysteine, methylmalonic acid, and 2-methylcitric acid in dried blood spots by tandem mass spectrometry
Turgeon CT , Magera MJ , Cuthbert CD , Loken PR , Gavrilov DK , Tortorelli S , Raymond KM , Oglesbee D , Rinaldo P , Matern D . Clin Chem 2010 56 (11) 1686-95 BACKGROUND: Newborn screening (NBS) for inborn errors of propionate, methionine, and cobalamin metabolism relies on finding abnormal concentrations of methionine and propionylcarnitine. These analytes are not specific for these conditions and lead to frequent false-positive results. More specific markers are total homocysteine (tHCY), methylmalonic acid (MMA), and methylcitric acid (MCA), but these markers are not detected by current NBS methods. To improve this situation, we developed a method for the detection of tHCY, MMA, and MCA in dried blood spots (DBSs) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). METHODS: The analytes were extracted from a single 4.8-mm DBS punch with acetonitrile:water:formic acid (59:41:0.42) containing dithiothreitol and isotopically labeled standards (d(3)-MMA, d(3)-MCA, d(8)-homocystine). The extract was dried and treated with 3 N HCl in n-butanol to form butylesters. After evaporation of the butanol, the residue was reconstituted and centrifuged and the supernatant was subjected to LC-MS/MS analysis. Algorithms were developed to apply this method as an efficient and effective second-tier assay on samples with abnormal results by primary screening. RESULTS: The 99th percentiles determined from the analysis of 200 control DBSs for MMA, MCA, and HCY were 1.5, 0.5, and 9.8 mumol/L, respectively. Since 2005, prospective application of this second-tier analysis to 2.3% of all NBS samples led to the identification of 13 affected infants. CONCLUSIONS: Application of this assay reduced the false-positive rate and improved the positive predictive value of NBS for conditions associated with abnormal propionylcarnitine and methionine concentrations. |
- Page last reviewed:Feb 1, 2024
- Page last updated:May 06, 2024
- Content source:
- Powered by CDC PHGKB Infrastructure